A:Yes, beginning in 2007, all Pro, SE, and XL Series chargers have been equipped with the capability of displaying fault codes. Listed below are the possible fault conditions and what they mean: (These fault codes are also present on all Eagle Series chargers) RED BLINKING LED.NO BATTERY DETECTED This indication occurs whenever the charger circuitry cannot detect a battery. The charger circuitry will not allow charge current to flow under this condition. With the AC power supply cord unplugged, check the connection to the batteries for proper polarity (black wire to negative or -). Also check for corrosion free secure connections to the battery. Please call the factory at 1-800-742-2740 for further assistance.
In most cases, your cranking battery doesn't need much charging, so when it has reached full charge, it will take the 5 amps from that bank and distribute them to the two banks that are charging your trolling motor batteries which equals 7.5 amps per bank. The Bass Pro Shops XPS chargers are. Jan 02, 2009 Need Help with XPS® i 5/5/5 onboard charger. Like i said i bought the boat with the charger on it so i dont have the owners manual. Jetbrains All Products Keygenguru. Bass pro onboard charger. And onboard battery chargers like the Bass Pro XPS are intended to reduce the headaches of charging and. Overall the Bass Pro XPS charger is a solid. I looked at the Bass Pro Shops web site and do see the XPS i 5/5/5 charger, but did not find links to the owners manual that would help answer your questions. I do have a Guest dual onboard smart charger (two banks), so had links to their products and found that they have a triple smart charger in the same.
2 RED BLINKING LEDS.FORMING STAGE TIMEOUT SHUTDOWN This indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first 3 hours of charging. This indicates a possible battery problem and the charge cycle has been terminated at this point. The charger may be reset by disconnecting and reconnecting the AC power supply cord. Please call the factory at 1-800-742-2740 for further assistance. 3 RED BLINKING LEDS.OVERALL TIMER SHUTDOWN This indication occurs if the charger has not completed the charge cycle within the allowable factory set time period. This indicates a possible battery problem and the charge cycle has been terminated at this point. The charger may be reset by disconnecting and reconnecting the AC power supply cord.
Please call the factory at 1-800-742-2740 for further assistance. 4 RED BLINKING LEDS.INTERNAL OVERTEMP SHUTDOWN This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are above factory specified levels. This could indicate a possible charger problem and the charge cycle has been terminated. The charger may be reset by disconnecting and reconnecting the AC power supply cord. Please call the factory at 1-800-742-2740 for further assistance.
5 RED BLINKING LEDS.OVERVOLTAGE PROTECTION This indication occurs if the charger circuitry has detected that the output circuitry is possibly defective. Please discontinue use of the charger and call the factory at 1-800-742-2740.
A: Since all of our charging systems consist of totally independent chargers, it is very simple to troubleshoot to see where the problem lies. Simply swap the location of the affected bank and another bank on the two batteries and operate the PCS charger. If the light indications remain the same (same bank still does not light), please call us at 1-800-742-2740 or send us a message using the form below and we will work with you to resolve the problem. If the light indications are reversed on the PCS charger, this indicates that there may be a problem with the battery attached to the bank that will not light.